Email Us

The Future of Occlusion: Bite Registration Products and Techniques

Table of Content [Hide]

    63b87511-cb67-a0a3-4785-529e9988db11.jpg



    Bite Registration Functions


    For making occlusal registrations——

    · Reduce the possibility of elevation or lowering of the restoration

    · Reduce clinical occlusal adjustments and save chairside operation time

    · Reduce the possibility of restoration perforation due to overgrinding


    7d84fbba-520a-252e-e0f5-7c2cfc35f2fa.png



    Comparison of Different Bite Registration Materials


    57c6a50b-f377-f02f-a5da-66eb497069c6.png

    56384778-5752-7660-6506-026fc718b566.png  140d2a04-c18b-3dec-d472-6afe35190ff8.png



    Introduction of Upgraded PERFlT Bite Registration


     eb11ce62-f210-4287-270b-8c493020f6a4.png

    · Improved hardness: 89 to 90 hardness (24h)
    >> Excellent hardness ensures accurate bite.
    · Reduced fluidity: Whipped-cream-like consistency
    >>Suitable fluidity gives patients a good bite experience.
    · Scannable performance: can be used in digital processes.
    >>The bite registration can be scanned directly without powder.

    *Data from VinciSmile lab




    Operation Notes


    c1d856cd-a065-a616-523d-36a6d4f164e4.png


    √ Dispersed point support: At least three points of support are required
    √ Blow dry the teeth to reduce the influence of saliva
    √ Let the patient bite the material gently and keep still
    √ Maintain an appropriate length for the bite registration.
    √ Achieve clear bite results by removing excess parts.



    Clinical Case Guidance


    76d415ae-ab08-facb-92aa-522c33d50d34.png


    · Molars are missing.

    · Direct bite registration has poor stability.

    · Use wax to make a temporary base first.



    c3f81c7a-b0c8-2e9d-a715-2141a7c47d58.png


    · The bite registration is too short.

    · Poor stability and easy to fall off.



    450ba95e-386e-becb-dd42-363c4fa6046a.png


    · The interproximal gap and deep defect were not trimmed.

    · The right picture shows the correct result after trimming.



    dff9d3d2-b9b5-d1af-dfce-64cd81588e0a.png


    · The bite registration does not fit the model.

    · Use the more accurate plaster model instead of the 3D printed model.

    · Higher trimming techniques.



    8e5388d3-1346-fad0-aab2-d2fef0f7e7a8.png




    Products
    References
    Whenever and whatever you need, we would like to provide the best solution for you.
    Contact Us
    Address
    4010 Valley Blvd, Ste 104, Walnut, CA 91789